Download "user manual"
Transcript
400 V Class Table 9.2 400 V Class Inverters Model Number CIMR-L7Z 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 Rated output capacity (kVA) 7 9 12 15 22 28 34 40 54 67 80 106 Rated output current (A) 8.5 11 14 18 27 34 41 48 65 80 96 128 115 154 Max. applicable motor out- Output Rating put (kW) *1 Max. output voltage (V) 3-phase; 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.) Max. output frequency (Hz) 120 Hz max. Rated voltage (V) 3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz Power supply characteristics Rated frequency (Hz) Rated input current (A) 10.2 13.2 17 22 Allowable voltage fluctuation 41 49 58 78 96 + 10%, - 15% Allowable frequency fluctuation DC reactor Measures for 12-phase power rectification supply 32 ±5% Optional Built In Not possible Possible * 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa standard motor. When selecting the actual motor and Inverter, be sure that the Inverter's rated current is higher than the motor's rated current. * 2. A transformer with dual star-delta secondary is required on the power supply for 12-pulse-rectification. 9 9-3