Pigeon Point Shelf Manager User Guide The option -c removes (clears) the HPDL data or SDRs, respectively, from the target FRU Information. For example, the following commands can be used to update the Shelf FRU Information with new versions of HPDL data and SDRs on a shelf where the Shelf FRU Information is stored in two redundant EEPROMs on the backplane, accessed locally by the Shelf Manager: #clia #clia #clia #clia frudataw frudataw frudataw frudataw -d -s -d -s 20 20 20 20 1 1 2 2 std14slot.hpdl.bin.gz std14slot.sdr.bin.gz std14slot.hpdl.bin.gz std14slot.sdr.bin.gz 3.6.4.4 Placing HPDL Data and SDRs in the FRU Information for Specific FRUs This section addresses placing HPDL data and SDRs into the FRU Information for a specific FRU (e.g. a fan tray). This information is used by the Shelf Manager to amend the attributes of that FRU from the attributes for that FRU that are specified in the HPDL chassis definition. The following information about the FRU is supplied in the chassis definition and cannot be redefined by the HPDL data in the FRU: FRU site type and number Presence signal definition. Device selection definitions can be redefined by the HPDL data in the FRU; however a problem arises when several slots exist in the chassis for the same type of the FRU, and addresses of devices of the FRU are different between different slots. In that case, it is not possible to define device location information on the FRU level; it is possible to do that only on the chassis level. This consideration limits the possibilities of redefining device information on the FRU level. It is not necessary to have both HPDL data and SDRs in a given FRU Information area; only HPDL data or only SDRs may be present. For example, to change the power consumption of the FRU, it is sufficient to have only HPDL data. To change certain sensor attributes (e.g. the conversion formula, default threshold values or default hysteresis), it is sufficient to have only SDRs. One problem with using HPDL data in a specific FRU is how to correlate the sensor numbers in the description to the actual sensor numbers. The sensor numbers are assigned within an IPM controller, not within a specific FRU, so the same sensors on different FRUs of the same type have different numbers; and it is typically not known in advance in which slot a specific FRU is going to be placed. This problem is solved in the following way: the sensor numbers in the HPDL/SDR data for a specific FRU have relative numbers, and these numbers are correlated to the actual numbers in ascending order. For example, assume that the replacement SDRs describe sensors 1, 2, 3 and 4, and the sensor numbers for the corresponding FRU in the HPDL chassis definition are 124, 208, 209 and 210. In that case, the replacement SDR for sensor 1 applies to sensor 124; the replacement SDR for sensor 2 applies to sensor 208, and so on. Release 3.5.1 123 August 17, 2015