Download Instructions - Swinton Technology
Transcript
S600+ Instruction Manual Holding Register Analog Output number value to be read. Hz Hertz. I, J, K Integer Any positive or negative whole number, including zero. Intelligent I/O The Intelligent Input Output module (P144), also known as “IIO”. I/O Input and Output. IP Institute of Petroleum or Ingress protection standard, referring to British standard 5420 or International Electro-Technical Commission standard 144. IP2 In the calculations section of the generator, this option includes the Liquid Volume Correction Tables (53 or 54) for a non-US configuration. IPL 600 Interactive program loader; a tool used to transfer application programs from a PC to the S600. IS Intrinsic Safe. A technique used to prevent excess electrical energy, or faults, in instrumentation from causing explosions in hazardous atmospheres. Often found in the process industry. It is the only protection method accepted for use in Zone 0 hazardous areas. ISO International Organisation for Standards. A voluntary, non-treaty organization founded in 1946 which is responsible for creating international standards in many areas, including computers and communications. Its members are the national standards organizations of the 89 member countries, including ANSI for the U.S. See http://www.iso.org. ISO 5167 Measurement of fluid flow by means of pressure differential devices (such as orifice plates, nozzles, or Venturi tubes) inserted in circular cross-section conduits. ISO 6976 Natural gas calculation of calorific values, density, relative density and Wobbe index from composition. LED Light-Emitting Diode (an indicator). On the S600, a light to show the status of the S600 in a visual form. As examples, the Alarm LED shows the status of the machine by the color of the LED and communications between the main processor board and the IO boards is shown on the rear of the flow computer by use of the transmit and receive LEDs. Mantissa Numerically significant part of a floating-point number. Meter Correction An option applicable only to liquid turbine applications and used to correct the flow rate due to temperature and pressure effects on the body of the meter. Meter Linearisation An option used to correct the K Factor or Meter Factor of a pulse input according to the input frequency. This is used to correct discrepancies caused by the non-linearity of the transducer connected to the pulse input. Modbus A device communications protocol developed by Gould-Modicon and used on the station supervisory computer data link. Modem Modulator Demodulator; a device used to communicate with other equipment using a telephone network. Modulate Superimposing one signal upon another. MOV Motor Operated Valve; a valve that is motorized and requires a signal to drive the valve open, a signal to drive the valve closed, and has a two signals returning to the S600 to describe the valve as being open, closed, moving, or illegal. Multiplexor Multiple Input Selector. Noise Random electrical interference. L M N A-4 Glossary Revised Jan-11