Download PC - AMS Users Manual
Transcript
Slice Width This specifies how monitoring window will be separated into slices for analysis. The size of the slice is dependent on the total Data Acquisition for the channel. The monitoring window is sliced into position dependent slices, and within each slice, an average force is computed. Each slice has an associated upper and lower limit, which is used when certifying the part. Slice Tolerance Slice Tolerance is used for widening the relative limits on a vertical rise. For each upper limit slice drawn, it compares the actual slice and then X number of slices before and X number of slices after the point and uses the highest value of the three. The lowest value is used for the lower limit. Where X represent the value of the Slice Tolerance set in the Advanced Setup. Force Monitoring W indow Relative Upper Limit Relative Lower Limit Start of W indow Slice Width End of W indow Position PC AMS User Manual •06/24/03 • Software Versions: 1.6.4 11429 East Grand River • P.O.Box 748 • Brighton, Michigan 48116 • (810) 229-9334 • FAX (810) 229-8125 E-Mail Address: [email protected] • Web Site: www.promessinc.com -10-