Gas Control Manager Program User Manual (FB107)
Field
Description
Prev Opened
Trail Run
Indicates the setting time (in seconds) that both valves
are open during the transition period between tubes.
This feature applies only if you have disabled the
Leave Open After Opening Next Tube option on the
Run Switch tab.
Lo Switch Pt
Indicates the low value that the program compares to
the value of the Input TLP for each run.
Note: The units of this field are actual Engineering
Units (not percentages).
Hi Switch Pt
Indicates the high value that the program compares to
the value of the Input TLP for each run.
Note: The units of this field are actual Engineering
Units (not percentages).
2. Click Apply to save your changes.
3. Proceed to Section 3.1.4, Run Switching – Proportional Output Tab.
3.1.4.
Run Switching – Proportional Output Tab
Eight proportional outputs are available that send selected inputs points to
analog outputs. Station 1 contains the 1st to 4th Output, while Station 2
contains the 5th to 8th output.
Figure 14. Run Switching screen – Proportional Outputs tab
Issued Aug-14