Download 1. - Omron
Transcript
SECTION 9 Troubleshooting Countermeasure Examples The following are only a selection of examples of possible countermeasures. Reading operation will not necessarily be improved by performing the following operations and so execute a reading to confirm correct operation. Items Possible problem Dot code Hollowing of dots • The influence of hollowing can be decreased by increasing the field of vision and thereby decreasing the size of the code image. • The influence of dots can be reduced by activating the Dilate or Erosion function of 0. Image Adjust/Filtering. • The influence of dots can be further reduced using the smoothing function (0. Image Adjust/Filtering retry). The influence of hollowing can be decreased by adjusting the BGS levels (0. Image Adjust/BGS levels). Refer to page 94 (Sec.5). Improving Reading Lighting Before countermeasure After countermeasure Before countermeasure After countermeasure SECTION 9 Improve reading accuracy by using the optimum lighting for the reading object. Example: Try the following countermeasure when performing reading for a code created by direct marking with a laser on stainless steel. Before countermeasure (Oblique Lighting) 248 V530-R160 Operation Manual After countermeasure (Coaxial Lighting)