Download 1. - Omron
Transcript
SECTION 3 Connection to the Host Connecting through the Serial Interface The V530-R160's serial interface (RS-232C/RS-422 connector) can be used to connect input signals such as reading triggers or output signals such as reading judgements. Additionally, data that has been set in the V530-R160 can be backed up in a personal computer. The connection method is explained here. For details on how to set the communication specifications and the I/O format, see SECTION 8 Communications with the Host. n Points to Check before Starting Communications SECTION 3 Connecting through the Serial Interface 60 Check the following points before starting communications using the serial interface. Points to check Is the cable connected properly? Check the cable type, pin numbers, and signals names. Are the SYS/Communication settings appropriate? • Is the communications mode setting at SYS/Communication/RS-232C/ 422 appropriate? For a no-protocol connection ••• Normal For a host link connection ••• Host link • When the 1:1 connection is made, is the SYS/Communication/Multidrop setting OFF? • Is the SYS/Communication/Data Output Setting/Polling setting OFF? Is the controller set to the RUN mode? p.61 p.206 (Sec.8) p.233 (Sec.8) p.209 (Sec.8) p.210 (Sec.8) − If there is no problem with these settings but proper communications cannot be established, see SECTION 9 Troubleshooting. Refer to page 257 (Sec.9) V530-R160 Operation Manual