RESET-clearing down the device Press BlackOut and switch on the device. After 4.sec display screen "CC" and whole memory of the device clear down. Setting size of packet Press AUDIO/WRITE and switch on the device. After 4 sec display hexadecimal value big as a input packet. By buttons PRG UP and PRG DOWN you adjust the value and confirm by BlackOut. Size of input packet determine way of CAPTURE regulation of notation into memory. For illustration: DMX controller USC-128 transmit in maximal configuration /16 scanners-8 channels/ 128 B packet /16x8/. It means that in case of setting packet on size FF / can be 00/ is packed big 256 bytes and 128 bytes is idle and takes place in memory witch you can use other way. Choice of some hexadecimal values: hexa decimal hexa decimal 10 16 60 96 20 32 80 128 40 64 FF 255 Protection of written programs In case you want to save your data written in memory you can use program Lock. The Lock is applied by following way : 5 by button PRG DOWN and PRG UP you choice program 5 by pressing BlackOUT, PRG DOWN, PRG UP together you lock or unlock an actually program. According to condition on a display is "CL" - closed/lock/, "oP" - open /unlock/. 5 If you want to rewrite locked programs, on a display is "CL" and don´t allow write. Technical specification Supply voltage Fuse Power consumption Weight Dimensions DMX input/output adapter 12V T 100mA 5x20mm 10VA 1 Kg 205x160x45 DMX 512 /1990/ 4us, 6,35 stereo Jack /Data+, Data,-, OV/ Your distributor :