PARVEX Motion Explorer Software - DIGIVEX Motion Module Let's take as an example a 360° rotary plate. If the user selects a lower limit of -180° and an upper limit of +180°, the axis position will always be between -180° and +180° whatever the cumulative movements made by the axis. The position set-points and the measured positions will be taken to be "modulo 360°". (The modulo corresponds to the difference upper limit - lower limit.) "Apply the specified modulo" means the user does not need to control the equivalence relation between the absolute positions -180° and +180°. Applying a modulo with an upper limit of +180° and a lower limit of -180° to the value of 470° returns 110° (470° - n times the modulo, where n = 1); applying it to a value of -200° returns +160° (-200° + n times the modulo, where n = 1). When a movement is requested, motion is not controlled with the notion of the "shortest path". A request for movement to the absolute position 900° will make the plate turn through 2 1/2 revolutions. When motion is completed, the position counter will show +180° (900° - n times the modulo, where n = 2). The modulo function also makes it possible to avoid reaching the maximum counting capacity of the system. Unless otherwise specified by the user, the system will apply of its own accord and as a safety measure a modulo with an upper limit of 10000000 unit1 (or 100000000 encoder transitions) and for the lower limit a lower limit value of -10000000 unit1 (or -1000000000 encoder transitions). Tip: the modulo upper limit and modulo lower limit values must correspond to a complete number of encoder increments or encoder emulation increments so as to avoid losing remainders from division operations. Apply modulo specified Check D this box to validate the modulo specified by the upper limit and lower limit fields below. [corresponding parameter: modul1_en] If this box is not checked, the system modulo will be applied. Modulo upper limit Enter the value of the upper threshold of the modulo in this field. [corresponding parameter: modul1_up] Modulo lower limit Enter the value of the lower threshold of the modulo in this field. [corresponding parameter: modul1_low] 5.2.1.5 Movement In this field, enter the selected acceleration / deceleration level, expressed in unit1/s2. See the Setting Calculation tab in the Servocontrol Settings window for information on programming values. [Corresponding Parameter: accel_max] In this field, enter the stop window value desired in unit1. This value is used Stop Window to declare the end of a movement (axis stationary). [Corresponding Parameter: target] In this field, enter the maximum speed of the application expressed in unit1/s. Max. Speed for See the Setting Calculation tab in the Servocontrol Settings window for Application information on programming values. [Corresponding Parameter: speed_max] Maximum Tracking In this field, enter the maximum tracking error authorized, expressed in unit1. [Corresponding Parameter: trackerror_max] Error Acceleration / Deceleration 30 PVD 3516 GB 04/2004