Transcript
134 Maintenance AXIOM™ / AXIOM-X™ Product Line Manual Cleaning the Exit Window WARNING: Shut down the reader before performing this maintenance task. Do not stare into the exit window at the laser light. Avoid direct eye exposure. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. CAUTION: Never apply cleaning solution directly to the exit window. Always apply the solution to a cloth, and then the cloth to the window. Do not use any chemical on the reader that is unsafe for plastics, such as benzene, acetone, or similar products. The exit window cleaning procedure may be performed without removing the reader from the mounting structure if it is possible to do so. 1. Turn off the reader’s lasers. (See Laser Shutoff.) 2. Follow the exterior cleaning procedure before cleaning the exit window. 3. Check the exit window surface for any dust, dirt, or smudges. If the window needs to be cleaned, proceed to Step 4. 4. Make a solution of seven parts denatured alcohol and three parts water. 5. Apply the cleaning solution to a cotton swab or lint-free cloth. 6. Apply the cleaning solution to the exit window. 7. Remove any streaks or remaining moisture from the exit window with a dry, soft, lint-free cloth or lens paper. 8. Turn the reader’s lasers back on. 9. Verify reader operation. Follow the Operations Checklist procedure in Chapter 5. AXIOM AXIOM-X Accu-Sort Systems, Inc. 07-AXIOM-AXIOM-X_Maintenance_R10.doc