Download PMD 180 - Uticor

Transcript
PMD 180 Message Display
User’s Manual
UTICOR Technology, LP
6
CHAIN MESSAGE
Message Attributes
[Y] A chain message will automatically display a group of other
messages. The chained message contains a list of message numbers to
be displayed. No message text is entered, only message numbers.
Example: Message 2 is a chained message
1> 25
2> 125
3> 34
4> 9
When message 2 is selected, then messages 25, 125, 34 and 9 will
automatically be displayed for a predetermined time. Each message in
the chain will be displayed for the same amount of time. Refer to “System Attributes Section” for setting the chain time. All chain messages
will use this time setting. The maximum number of messages in a chain
is 115.
Repeat Chain
[Y] Will cause the list of chain messages to repeat until a new message
is selected.
[N] Will display the list of chain messages once.
SCROLL UPWARDS
[Y] Message lines will scroll up from a lower line of the display to next
line up of the display. The maximum number of characters in a scroll up
message is 235.
Bottom Line/Top Line
The message will scroll from the selected bottom line to the selected
top line. The bottom line value must equal to or greater than that of the
top line.
Repeat
[Y] The scroll up message will keep repeating until a new message is
selected.
[N] The scroll up message will be displayed once.
Scroll Rate
79736-6
Determines the rate this particular message will scroll up. The range for
scroll rate is 0.1 to 9.9 seconds. A value of 0.0 causes the PMD to use
the value found in the system attributes.
39