Download HP LeftHand Storage Solutions
Transcript
CHAP is optional. However, if you configure 1-way or 2-way CHAP, you must remember to configure both the server and the iSCSI initiator with the appropriate characteristics. Table 74 lists the requirements for configuring CHAP. Requirements for configuring CHAP Table 74 Configuring iSCSI CHAP CHAP Level What to Configure for the Server in the SAN/iQ Software What to Configure in the iSCSI Initiator CHAP not required Initiator node name only No configuration requirements • CHAP name* Enter the target secret (12-character minimum) when logging on to available target. 1-way CHAP • Target secret • Enter the initiator secret. (12-character minimum). • CHAP name* • Target secret 2-way CHAP • Enter the target secret (12-character minimum). • Initiator secret * If using CHAP with a single node only, use the initiator node name as the CHAP name. iSCSI and CHAP terminology The iSCSI and CHAP terms used vary based on the operating system and iSCSI initiator you are using. The table below lists the terms for two common iSCSI initiators. Table 75 iSCSI terminology SAN/iQ CMC Microsoft VMWare Linux Refer to the documentation for the iSCSI initiator you are using. Linux iSCSI initiators may use a command line interface or a configuration file. Initiator Node Name Initiator Node Name iSCSI Name CHAP Name Not used CHAP Name Target Secret Target Secret CHAP Secret Initiator Secret Secret N/A NOTE: The initiator node name and secrets set in the SAN/iQ CMC must match what you enter in the server’s iSCSI initiator exactly. 338 iSCSI and the HP LeftHand Storage Solution