24
376
kVA
i
f
n
Assembler – Examples
"Table positioning" sample program
Hz
P Hz
Program start
==========================================
Initialization
-----------------------------------------SET H300 = 15000
SET
H301 = 15000
SET
H302 = 1000
SET
H303 = 1000
------------------------------------------
Set speed and acceleration values for table positioning (see variable description in the remarks for the
program source code)
Program branch distributor
==========================================
SETINT ERROR
M10
M100: CALL
M50
JMP
LO I0001000000000000, M101
CALL
M20
M101: JMP
LO I0000010000000000, M102
CALL
M30
M102: JMP
LO I0000100000000000, M103
CALL
M40
M103: JMP
UNCONDITIONED , M100
------------------------------------------
Program branch distributor
Activate interrupt routine for hardware limit switch processing reset/move clear of limit switch → main program
DI16 = 1 → Reference travel
DI14 = 1 → Jog CW
DI15 = 1 → Jog CCW
Subroutine/move clear of limit switch
==========================================
M10: JMP
HI I0000000000110000, M1
M3: JMP
HI I0000000000110000, M2
ASTOP
IPOS ENABLE
JMP
UNCONDITIONED , M3
M2: ASTOP
TARGET POSITION
M1 : RET
------------------------------------------
Reset/move clear of limit switch
If drive has not moved onto limit switch (DI04/DI05
Limit switch CW/CCW), then return to branch distributor. If it has, then unlock travel and wait until drive has
moved clear of limit switch (parameterized "Reset"
input function DI02).
Then stop drive by setting target position to current
position
Reference subroutine
==========================================
M20: ASTOP
IPOS ENABLE
AND
H480 & FFFFFFF0 hex
BCLR
H480.5 = 0
GO0
U,NW, ZP
M22: JMP
LO I0000000000000001, M21
SET
H319 = 0
BMOV
H319.0 = H473.20
JMP
H319 == 0
, M22
M21 : ASTOP
TARGET POSITION
RET
------------------------------------------
Reference travel
Travel release
Delete output binary coded table position
Delete output "Table position valid"
Reference travel, no wait, start at zero pulse,
as long as "Controller inhibit" = 0
and the bit in the status word "IPOS Reference" = 0
Subroutine jog mode
==========================================
M30: RET
M40: RET
Option: Subroutine (e.g. jog mode)
Jog CW
Jog CCW
Manual – IPOSplus®