Download CONNEXION® - MANAGER
Transcript
CONNEXION® - MANAGER User manual Rejection boundaries The entered rejection boundaries are allocated to the fields that are defined in the inspection procedure. The tab card Rejection boundaries only shows the fields present in the inspection procedure that have been ® selected for the script commands which are related to the execution of a measurement with the PLEXOR test device. When the mouse cursor is moved over the field number it shows the name of this field as used within the result database. Depending on the type of script command linked to a field number, it is possible to make the selection in units 3 as [mbar] or [bar] or in case of a leakage value measurement as [mbar/min] or [dm /h]. When the leakage value is measured INSPECTOR will, depending on the unit chosen, validate the inspection result on the basis of the rejection boundaries entered for leakage value or leakage rate. It is possible to export and to import rejection boundaries. With this possibility the rejection boundaries of gas control lines can be entered efficiently with the same inspection procedures. Definition of rejection boundaries of a gas control line in MANAGER 30 CONNEXION® MANAGER DDO2111GHGB / 10.2009 / Rev. 04