Download Sunny SensorBox
Transcript
Accessories SMA Solar Technology AG 13.4 Ambient Temperature Sensor 13.4.1 Packing List SMA order number,: TEMPSENSOR-AMB A B C 1 2 2 JUMO PT100 Sensor Screws Screw anchor 13.4.2 Cabling Recommendations The cable length and quality have an effect on the signal quality. To achieve a good quality signal, observe the following instructions regarding cabling: Outdoors For the outdoors, use a cable with the following key properties: • Cross-section: min. 4 x AWG 24 • External diameter: min. 1.18 in., max. 0.28 in. • UV-resistant • The maximum cable length may not exceed 98 ft.. We recommend the following cable types: • UL-listed Lapp cable: UNITRONIC LifY11Y 4 x 0.34 mm², order no.: 7038 865 Indoors or Using a Cable Channel If you protect the cable from UV radiation outdoors by means of a suitable cable channel, you can also use a non-UV-resistant (indoor) cable with the basic properties mentioned above. We recommend the following cable types: • UL-listed Lapp cable: UNITRONIC LiYY UL/CSA 4 x AWG22/7, order no.: 0022 604 62 Sensorbox-IUS084413 Installation Guide