Starting with PCB revision 1179.6 the phyCORE Carrier Board
HD200 features 4 solder jumper (J1-J4) that allow signal routing for
GPIO37-GPIO40 to different connectors; the Ethernet interface X7 or
the Expansion Bus X2. The standard configuration of the
phyCORE-LPC2292/94 provides Ethernet signals on these pins. As a
result the default configuration of Jumpers J1-J4 will route the signals
to Ethernet interface connector X7. Changing this jumper default
configuration allows use of the signals on the Expansion Bus in
combination with a phyCORE module lacking the Ethernet controller.
Jumper
J1 - J4
Setting
1 + 2*
J1 - J4
2+3
Description
Signals GPIO37-GPIO40 configured as Ethernet signals
routed to X7
Signals GPIO37-GPIO40 routed to Expansion Bus
* = Default setting
Table 79:
Solder Jumpers J1 - J4 Configuration Ethernet Interface