phyCORE-LPC2292/94 Caution: When using the DB-9 socket P1B with the configuration of the phyCORE-LPC2292/94 as described above the following jumper settings are not functional and could damage the module: Jumper JP1 Setting open JP2 closed JP3 closed JP4 closed JP5 closed JP6 closed JP7 closed JP8 open Table 55: Description Pin 2 of DB-9 socket P1B not connected, no connection to TxD1 signal from phyCORE-LPC2292/94 Pin 9 of DB-9 socket P1B connected with port P1.18 from phyCORE-LPC2292/94 Pin 7 of DB-9 socket P1B connected with port P0.22 from phyCORE-LPC2292/94 Pin 4 of DB-9 socket P1B connected with port /PCS0 from phyCORE-LPC2292/94 Pin 6 of DB-9 socket P1B connected with MOSI0 signal from phyCORE-LPC2292/94 Pin 8 of DB-9 socket P1B connected with port P0.21 from phyCORE-LPC2292/94 Pin 1 of DB-9 socket P1B connected with port P1.19 from phyCORE-LPC2292/94 Pin 3 of DB-9 socket P1B not connected, no connection to RxD1_ext. signal from phyCORE-LPC2292/94 Improper Jumper Settings for DB-9 Socket P1B (Second RS-232) If an RS-232 cable is connected to P1B by mistake, the voltage level on the RS-232 lines could destroy the phyCORE-LPC2292/94. 94 © PHYTEC Meßtechnik GmbH 2006 L-658e_5