Download RainMaster RME Eagle Controller Owners Manual
Transcript
RME EAGLE User Manual Rain Master Irrigation Systems EXAMPLE: If you have the optional wireless communications product installed, the communications are enabled as follows: Continue to Press: SETUP COMM OFF Until display indicates: CODE PROGRAM Press: 1 SUN ENTER The 1 key acts as a toggle key when used in this SETUP configuration item. COMM ON Display will indicate: PROGRAM QUIT Press: The controller will return to the Automatic Mode. 6.13 FLOW SENSOR This Flow enable/disable feature allows you to select whether you are using a flow sensor or not. For a general description of how the flow features work, see 9.2 FAULT DETECTION OVERVIEW chapter of this manual. Note: The remaining SETUP features are related to the Flow Sensor features and will be skipped if the Flow Sensor features have not been enabled. EXAMPLE: If you have a Flow Sensor connected to the controller and you wish to activate the Flow Sensor features. Continue to Press: SETUP FLOW Until display indicates: CODE PROGRAM Press: Page 74 1 SUN ENTER The 1 key acts as a toggle key when used in this SETUP configuration item. Chapter 6 Setup Key Operations