Download DUO`PULSE Pump - Ntn

Transcript
Picture 1: DUO'PULSE 100 Kg
Picture 2: DUO'PULSE 30 Kg
3. IDENTIFICATION OF THE PUMP
On the front part of the pump tank there is a plate which indicates the product code, the supply voltage and the basic
characteristics.
4. TECHNICAL CHARACTERISTICS
The pump consists of a series of components with the following characteristics:
Max. pressure
Outlet delivery
Working temperature
Working humidity
Viscosity at working
temperature
Technical characteristics
400 bar
400 cm3 / min (24 cu. in/min)
(2 x 200 cm3 (12 cu. in) pump modules )
da - 5° C a + 50° C (da 23° F a +122° F)
90% max
Mineral oil lubricants
Min. 32 cSt
Grease lubricants
Viscosity at working
temperature
Degree of protection
Electric motor
NGLI 2 Max.
IP 55
Three phase
Power:
0.75kW
Protection IP55 class B
Voltage:
230-400 Volt ± 5% 50 Hz
240-440Volt ± 5% 60 Hz
S1 continuous service.
N.B.: do not supply the machine with voltages and pressures different from those indicated
on the plate.
3/ 26