Download Q Corresponding Etherne Interface Module User`s Manual
Transcript
6 DEDICATED INSTRUCTIONS MELSEC-Q 6.6 RECVS Instruction (for Interrupt Programs) This instruction reads received data. Applicable device MELSECNET/H, Set Internal device data Bit File register Word MELSECNET/10 Direct J \ Bit Special module Index register Zn U \G Constant Others K, H Word (S) — — (D1) — — (D2) — [Instruction symbol] [Executing condition] Command Z.RECVS "Un" (S) (D1) (D2) RECVS Set data Set data "Un" Description Start I/O signal of the local station's Ethernet net module. (00 to FE: The higher 2 digits of the 3-digit I/O signal.) (S) Head device of the local station that stores the control data. (D1) Head device of the local station that stores the receive data. (D2) (Designate as dummy.) Set by Data type User Character string User, system System Device name Bit The local devices and the file register for each program cannot be used as devices used in setting data. POINT The RECV instruction can be executed only when the local station is a QCPU. REMARK The number of steps for the RECV instruction is 10. 6 - 22 6 - 22