General Precautions Warnings and Cautions alert users to dangerous conditions that can occur if instructions in the manual are not obeyed. Warnings are conditions that can cause injury to the operator, while Cautions can cause damage to the device and internal electronics. WARNING: Proper use of this device depends on careful reading of all instructions and labels. WARNING: Electrical shock hazard when connected to 300 V bias supply. Do not disassemble the QA BeamChecker Plus. WARNING: Where applicable, Standard Imaging products are designed to be used with the versions of common radiation delivery devices, treatment planning systems and other products or systems used in the delivery of ionizing radiation, available at the time the Standard Imaging product is released. Standard Imaging does not assume responsibility, liability and/ or warrant against, problems with the use, reliability, safety or effectiveness that arise due to the evolution, updates or changes to these products or systems in the future. It is the responsibility of the customer or user to determine if the Standard Imaging product can be properly used with these products or systems. CAUTION: This device should never be submerged in any liquid, scrubbed with an abrasive cleaner, or be stored or placed where liquids could be spilled or splashed onto it. CAUTION: Do not drop, mishandle, or disassemble this device. Refer all servicing to qualified individuals. CAUTION: Do not irradiate this device past the 20 x 20 cm field label edge. CAUTION: Always use the QA BeamChecker Plus in the same orientation during Baseline Setup, Wire-Free, or Real-Time Operation Modes. Improper comparative measurements and/or out of tolerance fault messages will occur if used in a different orientation. CAUTION: To help ensure measurement reproducibility over time and minimize possible backscatter effects from the treatment couch, especially for low energy photons, position the device in the same location on the treatment couch for every measurement. 2 CAUTION: When using the Bluetooth® Adapter Kit, be careful lifting the unit when it is laying flat to avoid damage to both the adapter and QA BeamChecker Plus. If necessary, remove the adapter before moving the unit. CAUTION: The Bluetooth Adapter Kit will not communicate through the treatment vault wall, but because their signal is transmitted via RF, the cradle (with attached adapter) can be placed inside a cabinet or closet and still communicate effectively. CAUTION: When using TomoTherapy® or Dynamic 5 Channel modes, only the photon side of the QA BeamChecker Plus should be used. CAUTION: When performing Baseline or Real-Time Operation measurements, ensure the proper room is selected to avoid overwriting or adding new data to the wrong room. CAUTION: In Physics Mode, no measurement data is stored within the database file. Data can only be saved by utilizing the Export .csv function. CAUTION: It is recommended to avoid screwing the serial cable into the unit and instead relying on the inherent pressure fit of the connection. If the cable catches on an obstruction during gantry rotation, damage can occur if the connector cannot pull free. CAUTION: Before upgrading to a new version of QA BeamChecker Plus software, download any Wire-Free data to the database. CAUTION: Use provided power supply or equivalent as identified by Standard Imaging. Contact Standard Imaging for additional information. CAUTION: To ensure long-term performance of the internal battery, it is recommended to fully recharge the QA BeamChecker Plus monthly. TomoTherapy® is a registered trademark of TomoTherapy Incorporated. Bluetooth® is a registered trademark of Bluetooth SIG, Inc.