Appendix 5.2 One shot ladder (1) Output starts and continues for a certain time after input X1 is turned on. (Time for the input being on must be longer than the set time limit.) 0 K70 T15 X1 T15 Y75 CIRCUIT END X1 T15 normally close Y75 Set time limit 7s (2) When the input X0 is turned on momentarily, Y76 turns on for a certain time. 0 X0 K100 T16 T16 Y76 Y76 CIRCUIT END (3) Output starts and continues for a certain time when the input X0 is switched from on to off. 0 3 X0 M1 PLF T16 M1 K100 T16 Y76 Y76 CIRCUIT END X0 Y76 Set time limit 10 s App - 92 Pulse width