Set by (When set) U (END) New S (Status change) New Set by (When set) • Always ON S(Every END processing) M9036 • Always OFF S(Every END processing) M9037 S(Every END processing) M9038 S(Every END processing) M9039 S(Every END processing) New S(Every END processing) New S (Status change) New Meaning Explanation • Asynchronous mode Mode in which the operation of the low speed execution type program is performed continuously within the excess Operation mode for low OFF: Asynchronous time. SM330 speed execution type mode • Synchronous mode program ON: Synchronous mode Mode in which the operation of the low speed execution type program is not performed continuously and operation is performed from the next scan even if there is excess time. • The status of the intelligent function module access instruction executed immediately before is stored. ON indicates completion (This data is overwritten when the intelligent function SM390 Access execution flag of intelligent function module access module access instruction is executed again.) • Used by the user in a program as a completion bit. Corresponding CPU Name Corresponding ACPU M9 No. Corresponding ACPU M9 Special Relay List (Continued) QCPU No. Name SM400 Always ON SM401 Always OFF Meaning ON OFF ON OFF SM402 After RUN, ON for 1 scan only ON OFF 1 scan SM403 OFF for 1 scan only after RUN ON OFF 1 scan ON OFF 1 scan ON OFF 1 scan ON for 1 scan only after SM404 low speed execution type program RUN OFF for 1 scan only after low speed SM405 execution type program RUN SM409 0.01 second clock SM410 0.1 second clock SM411 0.2 second clock SM412 1 second clock SM413 2 second clock SM414 2n second clock SM415 2n (ms) clock SM420 SM421 SM422 SM423 SM424 SM430 SM431 SM432 SM433 SM434 User timing clock No. 0 User timing clock No. 1 User timing clock No. 2 User timing clock No. 3 User timing clock No. 4 User timing clock No. 5 User timing clock No. 6 User timing clock No. 7 User timing clock No. 8 User timing clock No. 9 0.005 sec. Explanation • After RUN, ON for 1 scan only • This connection can be used for scan execution type programs only. • After RUN, OFF for 1 scan only • This connection can be used for scan execution type programs only. • After RUN, ON for 1 scan only • This connection can be used for low speed execution type programs only. • After RUN, OFF for 1 scan only • This connection can be used for low speed execution type programs only. • Repeatedly changes between ON and OFF at 5-ms interval. • When turned OFF or reset, goes from OFF to start. 0.005 sec. 0.05 sec. 0.05 sec. S (Status change) n sec. • Alternates between ON and OFF at intervals of seconds specified in SD414. S (Status change) n(ms) • Alternates between ON and OFF at intervals of the time (unit: ms) specified in SD415. S (Status change) New S (Every END processing) M9020 M9021 M9022 M9023 M9024 S (Every END processing) New 0.1 sec. 0.5 sec. 0.5 sec. 1 sec. n(ms) • Relay repeats ON/OFF switching at fixed scan intervals. • When turned ON or reset, goes from OFF to start. • The ON/OFF intervals are set with the DUTY instruction. n2 scan n2 scan DUTY n1 n2 SM420 n1 scan • For use with SM420 to SM424 low speed programs App - 54 M9031 M9032 M9033 1 sec. n sec. QCPU M9030 • Repeatedly changes between ON and OFF at each designated time interval. • When turned OFF or reset, goes from OFF to start. Note that the ON-OFF status changes when the designated time has elapsed during the execution of the program.) 0.1 sec. Corresponding CPU (3) System clocks/counters M9034 format change QCPU