Section 9-1
Error Counter Reset Output
9-1
Error Counter Reset Output
The Error Counter Reset Output Dialog Box can be used to turn the error
counter reset output signal ON and OFF.
Displaying the Error
Counter Reset Output
Window
1,2,3...
1. On the project tree, select the Position Control Unit for which to execute the
error counter reset output.
2. Select Online - Error Counter Reset Output.
3. The following warning dialog box will be displayed. Read the contents of
the warning carefully. Click the OK Button only after confirming safety.
4. The Error Counter Reset Output Dialog Box will be displayed.
Note
(1) ON/OFF control of the error counter reset output signal can be executed
with Position Control Unit with unit version 2.3 (with embedded software
version 2.3) or later.
To confirm the unit version of the Position Control Unit Version, refer to
the Unit Versions of Position Control Units on page vi.
(2) ON/OFF control of the error counter reset output can be executed when
the PLC is in PROGRAM mode. Execute the operation after changing the
PLC to PROGRAM mode using the CX-Programmer or Programming
Console.
Closing the Error
Counter Reset Output
Window
94
Click the Close Button at the right top corner of the error counter reset output
Window. The error counter reset output will be turned OFF for all axes.