Download OPERATING AND SERVICE MANUAL

Transcript
IRIG H (OPTION):
PARALLEL BCD
TIME (OPTION)
:
BNC output of standard IRIG H format TTL
DC level shift supplied unless otherwise
requested. If lkHz amplitude modulated
carrier requested, IRIG B will automatically
be supplied in D.C. Level Shift format.
See Section 3-52.
If ordered, Parallel BCD time of year is
provided on rear panel 50 pin "D" connector.
Days, hours, minutes, seconds and milliseconds are provided. Lines indicating
worst-case time error of +I, +5, +50 and
+500ms drives 2 standard w
~ loads
~
~
or w
wC~OS". See Section 3-56.
RS-232 (OPTION):
The displayed time of year is outputted
in EIA Standard RS-232C configuration via
a "Motorola ACIA". Output format is
D D D H H M M S S and an indicator of the
time quality, CR/LF. Baud Rate and "ACIA"
options are dip switch selectable.
See Section 3-67.
IEEE-488 (OPTION):
IEEE Buss interface is also available. The
time is outputted in ASCII format, with the
most significant digit first (100's of days).
Among operating modes is time on demand to
the millisecond level, or marked time to
the milliseconds level. See Section 3-99.
HOURS O F F S E T :
Rear panel thumbwheel switch allows adjustment of + or - "0" to "11" hours from
transmitted UTC time.
12/24-HR.
Dip Switch located inside unit allows use
as 12 hour clock in place of 24 hour format
as shipped.
468-DC
OPERATION:
S Y N C H R O N I Z E D D I G I T A L CLOCK
SIZE:
1-314" x 17" x lot.;" (4.4 x 43.2 x 26.7cm)
behind panel. Mounts in standard 19"
(48.9cm) EIA rack system, hardware included.
24" (60.9) hardware available.
WEIGHT:
7& lbs. (3.5kg) Ship Wt. 12 lbs. (5.4kg).
POWER:
95-135VAC, 60-400Hz, less than 25 volt
amps. Others available on request.
A-468MS
ANTENNA
SIZE:
12" x 12" x 7%" high (30.5cm x 30.5cm x 19.5cm)
provided with universal mounting and hardware.