Download Manual Change - Agilent Technologies
Transcript
The dierence between the measured value of the DUT and a previously stored reference value are displayed. The formula used to calculate the deviation is as follows. 1ABS = X 0 Y Where, X: The measured value of the DUT Y: The stored reference value 1% (Delta percent) deviation measurement The dierence between the measured value of the DUT and a previously stored reference value are displayed as a percentage of the reference value. The formula used to calculate the percent deviation is as follows. 1% = (X 0 Y) / Y 2 100 [%] Where, X: The measured value of the DUT Y: The stored reference value Front Panel Operation for the Deviation Measurement Function Perform the following steps to execute the deviation measurement function. 1. Move the cursor to the REF A eld to enter the reference value for the primary parameter. The following softkey will be displayed. NNNNNNNNNNNNNNNNNNNNNNNNNN MEA-SURE When the device which has a reference value is connected, pressing this MEA-SURE , the 4284A measures the device, and the measurement results are entered as a reference value for REF A and REF B values. 2. Enter the reference value for the primary parameter using MEA-SURE or the numeric entry keys. 3. Move the cursor to the (REF) B eld to enter the reference value for the secondary parameter. The following softkey will be displayed. NNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNN MEA-SURE When the device is to be used as the reference value is connected, MEA-SURE is pressed, the 4284A measures the device, and the measurement results are entered as a reference value for REF A and REF B values. 4. Enter the reference value for the secondary parameter using MEA-SURE or the numeric entry keys. If the reference values for A and B are entered using MEA-SURE in step 2, skip this step. 5. Move the cursor to the DEV A eld. The following softkeys will be displayed. NNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNN MEAS SETUP Menu 4-13
Related documents
Référentiel métier ACCROCHEUR – RIGGER
Samsung VP-HMX10 Camcorder User Manual
Samsung DVD-V9650 MP3 Player User Manual
Canon LBP-3300 User`s guide
Télécharger le dossier de presse
Agilent 4284A Precision LCR Meter
OPERATING AND SERVICE MANUAL Relay Accessories
Sunbeam RC5600 Rice Cooker User Manual
Migrating from an Agilent 4284A LCR Meter to an Agilent
Ford 2003 Explorer Automobile User Manual
Samsung DVD-V9700 User Manual
Caution - Keysight