Download Model XMT868
Transcript
June 2003 Table 1-27: MODBUS Registers (Continued) MODBUS DPR Hex Reg # Addr Units Scaling (decimal places) Size in Bytes AVG-Totals TOT_U Register 46 4 (32 bit integer) AVG #T Digits none 0 2 (16 bit integer) AVG Totalizer Time sec 2 4 (32 bit integer) none 0 2 (16 bit integer) AVG SSUP none 1 4 (32 bit integer) AVG SSDN none 1 4 (32 bit integer) ft/s or m/s 0 4 (32 bit integer) Description 3 44 46 3 47 4 49 AVG Error Value 50 3 52 3 54 3AVG SNDSP 56 CH 1 Power Power_u -- 4 (IEEE 32 bit) 58 CH 1 +Energy Energy_u Register 62 4 (32 bit integer) 60 CH 1 -Energy Energy_u Register 62 4 (32 bit integer) 62 CH 1 # Energy Digits none 0 2 (16 bit integer) 63 CH 1 TempS °F or °C 2 4 (32 bit integer) 65 CH 1 TempR °F or °C 2 4 (32 bit integer) 67 CH 1 TS-TR °F or °C 2 4 (32 bit integer) 69 CH 1 DELTH Btu/lb or J/gm 2 4 (32 bit integer) 71 CH 2 Power Power_u -- 4 (IEEE 32 bit) 73 CH 2 +Energy Energy_u Register 77 4 (32 bit integer) 75 CH 2 -Energy Energy_u Register 77 4 (32 bit integer) 77 CH 2 # Energy Digits none 0 2 (16 bit integer) 78 CH 2 TempS °F or °C 2 4 (32 bit integer) 80 CH 2 TempR °F or °C 2 4 (32 bit integer) 82 CH 2 TS-TR °F or °C 2 4 (32 bit integer) 84 CH 2 DELTH Btu/lb or J/gm 2 4 (32 bit integer) none 0 2 (16 bit integer) 6 MODBUS parity none 0 2 (16 bit integer) MODBUS stop bits none 0 2 (16 bit integer) 508 3F6 509 3F8 510 3FA 511 3FC MODBUS meter addr none 0 2 (16 bit integer) 512 3FE RESERVED none --- --- Programming Site Data 5MODBUS 7 baud rate 1-81