Download RVV NG Vender with 5-button Programming
Transcript
SECTION 5: Troubleshooting FIGURE 5.27. Y-axis pulleys Check the top pulleys and the pulley on the Y-motor to make sure they are not loose or slipping. Also, check the screws which secure the top idler assemblies to make sure they are not loose. Y-motor pulley Top left idler screw and pulley Top right idler screw and pulley 2. X-axis (left and right movement) a. Check the X-belt for proper tension. When the X-belt has proper tension, it should be firm but not tight. b. Check the X-motor pulley for slippage. (Refer to Figure 5.28.) If the pulley on the motor is loose, replace the motor. Also, check the X-belt idler pulley for slippage. No belt slippage on the pulleys should be heard while the X-belt is running. c. If tension is correct and neither pulley is found to be loose, replace the X-belt. FIGURE 5.28. X-axis motor pulley Check the pulley on the X-motor to make sure it is not loose or slipping, and check the X-axis belt for proper tension. No slippage should be heard when the X-belt is properly adjusted. Royal Vision Vender NG 5-button Service and Parts Manual 61