Download Operation Details
Transcript
CS-G90KE Operation Details B. Anti Cold Draft Control (i) Indoor Fan Control Indoor fan speed and airflow direction varies in accordance to the indoor heat exchanger temperature as shown below: a. Manual Fan speed control (Manual Airflow Direction Control) (Auto Airflow Direction Control) Min Me 58°C (58°C) Remote Control Setting Fan Speed 25°C (30°C) 18°C (28°C) 13°C (13°C) 55°C (55°C) Remote Control Setting Fan Speed 37°C (37°C) Lo- 24°C (29°C) SLo 15°C (21°C) 9°C (9°C) Stop Min Me 58°C (58°C) Indoor heat exchanger temp. 28°C (28°C) 13°C (13°C) 55°C (55°C) Lo- 29°C (29°C) SLo 21°C (21°C) 9°C (9°C) Stop Indoor heat exchanger temp. b. Auto Fan Speed Control (Auto Airflow Direction Control) 52°C (52°C) 37°C (37°C) Max UP (Manual Airflow Direction Control) Max or Up DOWN 32°C (32°C) Me 25°C (30°C) 32°C (32°C) DOWN 18°C (28°C) 13°C (13°C) DOWN Lo- 24°C (29°C) SLo 15°C (21°C) Stop 9°C (9°C) Indoor heat exchanger temp. Note: – – – – 37°C (37°C) 28°C (28°C) 13°C (13°C) Lo- 29°C (29°C) SLo 21°C (21°C) Stop 9°C (9°C) Indoor heat exchanger temp. UP means fan speed is increased by 1 rank. DOWN means fan speed is decreased by 1 rank. Max means fan speed is running at maximum auto fan speed. Temperature in ( ) is indicating when powerful mode is selected. – 25 – Untitled-5 25 6/29/00, 10:50 AM MAC9509078C2