Download GUIV Service Man
Transcript
PRODUCT IDENTIFICATION This section will identify the models covered and the changes per each model group from one release to the next. Model # Manufacturing # GUIS***CA** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "A" Standard Unit (not NOx certified). P1211003F - P1211008F 40" 80% two-stage furnace featuring integrated electronic ignition control, two-stage gas valve, two-speed induced draft blower, silicon carbide ignitor, electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger. GUIS***CX** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "X" NOx Certified. 40" 80% two-stage furnace featuring integrated electronic ignition control, silicon P1211103F - P1211107F carbide ignitor, two-stage gas valve, two-speed induced draft blower, electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger. GUIS070DA35 10 Description P1227103F Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "D" Fourth Design Series "A" Standard Unit (not NOx certified). 40" 80% two-stage furnace featuring integrated electronic ignition control, silicon carbide ignitor, two-stage gas valve, two-speed induced draft blower and 409 stainless steel tubular heat exchanger. Use of smooth cold rolled steel substrate and a smooth top coat for furnace cabinet to replace prepainted furnaces until new coating is approved for prepainted material. GUIS***CA** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "A" Standard Unit (not NOx certified). P1229803F - P1229808F 40" 80% two-stage furnace featuring integrated electronic ignition control, silicon carbide ignitor, two-stage gas valve, two-speed induced draft blower, prepainted textured steel cabinet and 409 stainless steel tubular heat exchanger. GUIS***CA** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "A" Standard Unit (not NOx certified). 40" 80% two-stage furnace featuring integrated electronic ignition control, silicon P1229903F - P1229907F carbide ignitor, two-stage gas valve, two-speed induced draft blower, electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger. Change from embossed bottom knock-out to perforated bottom knock-out and addition of internal side filter retention. GUIS***CX** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "X" NOx Certified. P1230003F - P1230007F 40" 80% furnace featuring integrated electronic ignition control, silicon carbide ignitor, prepainted textured steel cabinet and 409 stainless steel tubular heat exchanger. GUIS***CX** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "C" Third Design Series "X" NOx Certified. 40" 80% furnace featuring integrated electronic ignition control, silicon carbide ignitor, P1230103F - P1230107F electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger. Change from embossed bottom knock-out to perforated bottom knock-out and addition of internal side filter retention. GUIS***FA** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "F" Sixth Design Series "A" (not NOx Certified). P1246703F - P1246708F 40" 80% furnace featuring a new integrated electronic ignition control, silicon nitride ignitor, new wiring harness, electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger. GUIS***FX** Gas Furnace Upflow/Horizontal Induced Draft S 2-Stage, Air Command 80 SSE II Furnace "F" Sixth Design Series "X" NOx Certified. P1246803F - P1246807F 40" 80% furnace featuring a new integrated electronic ignition control, silicon nitride ignitor, new wiring harness, electrodepositioned textured steel cabinet and 409 stainless steel tubular heat exchanger.