Download M3060 Indicator
Transcript
3.4 6f. Power Connections - Battery If the battery terminals have bolts to which you can connect the ring terminals, do so. If not, skip to step 7. The ring terminal connected to the fuse holder should be attached to the positive (+) terminal. The ring terminal connected to the black wire should be attached to the negative (-) terminal. Skip to step 10. white wire To battery connection Power cable to indicator Figure 3.11 Fuse wiring Item 4 in Figure 3.11 is the fuse. It is PN AWT25-500337 and is a 3AMP 3AG SLOWBLOW FUSE. M3060 User Instructions 7. Connect the white power cable as close as possible to the battery's positive voltage terminal without attaching it directly to the battery terminal. In other words, the first place the positive terminal is connected to is where you should tap in with the white power cable for the instrument. 8. Connect the black ground cable as close as possible to the battery's negative terminal without attaching it directly to the battery. In other words, the first place the negative terminal is connected to is where you should tap in with the black ground cable for the instrument. The chassis may not provide the proper ground potential. Check with the equipment manufacturer to determine if battery ground is isolated from chassis ground. 9. Tighten the AMP connector on the underside of the indicator. See figure 3.9. 10. Reconnect battery power. 11. Press and hold the On/Off key on the M3060 until the red light above the key comes on. 12. Check that the instrument powers on. 21