Download d096 service manual appendices
Transcript
Service Call Conditions ADF connection error 621 B An incorrect ADF (an ADF ADF incorrect (The ADF for for some other copier) is B039/B040/B043 or B121/B122/B123 detected. is installed on this machine.) ADF gate abnormal 1 The ADF Gate signal line 760 B between the ADF main board and the BICU is disconnected. ADF main board defective Input/output board defective Poor connection (ADF Gate line) between the ADF main board and the BICU. ADF gate abnormal 2 The FGATE signal is not 761 B issued from the ADF within ADF connector defective 30 seconds after the ADF SBU board defective starts feeding. ADF gate abnormal 3 The FGATE signal is not 762 B terminated by the ADF ADF connector defective within 60 seconds after the SBU board defective ADF starts feeding. Mechanical total counter 901 B The mechanical total Mechanical total counter defective counter does not work BICU defective properly. Disconnected mechanical total counter Engine total counter error 903 B The checksum of the total counter is not correct. D096 3-10 NVRAM on the BICU defective SM Appendix