Download StorEdge 3310 Manual

Transcript
8.1.2
JBOD Disks Not Visible to the Host
If you attach a JBOD array directly to a host server and do not see the drives on the
host server, check that the cabling is correct and that there is proper termination.
Refer to the special cabling procedures in “Cabling JBODs” on page B-1.
If the cabling is correct and the drives are still not visible, run the devfsadm utility
to rescan the drives. The new disks can be seen when you perform the format
command.
If the drives are still not visible, reboot the host(s) with the reboot -- -r
command so that the drives are visible to the host.
8.2
Key Screens and Commands
8.2.1
The Controller Firmware Initial Screen
You see the following initial controller screen when you first access the RAID
controller firmware (via the controller COM port or Ethernet port).
To complete the connection to your management console, select the VT100 terminal
mode or the appropriate mode for your communications software, and press Return.
Chapter 8
Maintaining and Troubleshooting Your Array
8-3