Download Service Manual
Transcript
COMP CONNECTION DIAGRAM YEL M 21 208/230 1Ø POWER SUPPLY CHOKE CHOKE CONT 23 YEL 23 BLK BRN C C EQUIP GND INVERTER GRN BLK 11 21 L2 S M 5 EXV L1 COMP BLK 11 T2 CONT EQUIP GND CONTROL BOARD C TRAN CONT 5 T3 RED BLK 23 CHOKE INVERTER YEL 23 L1 INVERTER WHT RED GRN CHOKE YEL 230V 208V COM BLK COMPONENT ARRANGEMENT CONT T1 RED CHOKE WHT C T3 S RED BLK TRAN 24V T2 T1 RED BRN L2 SCHEMATIC DIAGRAM (LADDER FORM) BLK OFM MODEL PLUG CHART MODEL MODEL PIN RESISTANCE (K ) PLUG SIZE HK70EZ 1 - 4 (R1) 2 - 3 (R2) 5.1 11 001 24 5.1 002 18 36 5.1 003 24 48 5.1 004 33 60 230V C TRAN 24V OFM EXV 1 YEL PL5 BLU GRN/YEL RED/WHT BRN/YEL TRAN SEC1 SEC2 EXV PWM2 PWM1 CC PL5 1 BRN RED 5 PL3 PWM2 HPS PWM1 RVS PL4 PL3 SPT HPS PL2 ORG RVS PL11 CB OST RED BLK WHT GRN PL1 5 PL1 BLK RVS BLK PL6 INVERTER BARE RVS OST ORG OCT OAT A B C NO USE J2 FORCED DEFROST PL8 MODEL OAT UTIL C LS Y O CONT BLK OAT 1. 2. 3. 4. LS UNIT OPERATION MODEL J2 FORCED DEFROST LS Compressor Furnished With Inherent Thermal Protection. To Be Wired In Accordance With National Electric Code (N.E.C.) And Local Codes. Use Copper Conductors Only. Use Conductors Suitable For At Least 70ºC (167ºF). Two Wire A and B Required For Communication. Unit Contains 24 Volt Transformer To Power Control Board. If Outdoor Unit Improperly Grounded, Connect Indoor Ground To “C” Terminal. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or Equivalent Wire. Check All Electrical Connections Inside Control Box For Tightness. Do Not Attempt To Operate Unit Until Service Valves Have Been Opened. Must Use With Infinity User Interface Listed In Pre-sale Literature Only. HIGH PRESSURE SWITCH INVERTER DRIVE LIQUID LINE SOLENOID THERMISTOR (OUTDOOR AIR) THERMISTOR (COIL) OUTDOOR FAN MOTOR THERMISTOR (SUCTION) HPS INVERTER LS OAT OCT OFM OST Furnace or Fan Coil VS HP No Use D D C C B B B A A A C HUM C W O Y R OAT C and D not required on VS Heat Pump A12055 Fig. 5 – Infinity Furnace or Fan Coil Wiring with Communicating Variable Speed HP 7 RVS SPT STATUS TRAN UTIL REVERSING VALVE SOLENOID SUCTION PRESSURE TRANSDUCER SYSTEM FUNCTION LIGHT TRANSFORMER UTILITY CURTAILMENT 338633-101 REV. A Fig. 4 – Wiring Diagram — 25VNA Model sizes 2 -- 5 tons, 208/230--1 24vac C OAT NOTES: This Control Board Contains A Five Minute Short Cycle Protector. A Five Minute Delay Will Occur Between Compressor Off/on -LEGENDCycles. To Bypass Delay, Short Forced Defrost Pins For 1 Second Then Release. The Crankcase Heater Is Energized During Off Cycle Below 75ºF As Needed. FACTORY POWER WIRING FIELD POWER WIRING DEFROST TIME SELECTION - The Defrost Interval Time Can Be Field Selected, Dependent Upon Local Georgraphic FACTORY CONTROL WIRING Requirements. It Is Factory Set At 90 Minutes And Can Be Changed To Either 30, 60 Or 120 Minutes Via The User Interface. FIELD CONTROL WIRING User Interface Defaults to “AUTO”. COMPONENT CONNECTION DEFROST - Defrost Will Only Be Performed At Outdoor Temperatures Less Than 50ºF. Defrost Will Initiate When Time JUNCTION Selected Has Elapsed And The Coil Temperature Is Less Than 32ºF (+/-2ºF). It Will Terminate At 65ºF, 50ºF, or 45ºF (+/-5ºF), FIELD SPLICE As Needed Based On OAT. At Defrost Termination The Outdoor Fan Will Turn On 15 Seconds Before Switching The CONTROL BOARD CB Reversing Valve.. CONTACTOR COIL CC FIELD INITIATED FORCED DEFROST - (Shown As Forced Defrost On Board) By Placing A Jumper Across The Forced Defrost COMM SYSTEM COMMUNICATION Terminals For 5 Seconds, Or Longer, And Then Removing The Jumper The Unit Will Initate A Defrost Cycle Regardless Of Coil COMP COMPRESSOR Temperature. The Defrost Cycle Will Terminate At 65ºF (+/-5ºF) If Coil Termperature Is Above 32ºF Or Outdoor Ambient CONT CONTACTOR ELECTRONIC EXPANSION VALVE Temperature Is Above 50ºF, Defrost Mode Will Terminate After 30 Seconds Of Active Mode. EXV Humidifier PL8 A BC NO USE BLK 5. 6. 7. 8. User Interface (UI) OCT COMM STATUS COMM STATUS UTIL C LS Y O PL6 OCT CHOKE OCT BRN BRN CHOKE OST OST SPT INVERTER BLU/PNK BLU/PNK RED + WHT BLK PL11 PL2 SPT + - SPT HPS CC HPS PL4 CB YEL BLU EXV SEC1 SEC2