Download Service Manual
Transcript
External Muffler Factory Supplied Muffler (part # LM10KK003) Installation is Required On Every Installation: S A muffler is required to reduce noise transmitted to indoor through the line set. S Muffler must be installed outside the dwelling. Muffler can also be installed in vertical configuration for space consideration maintaining a minimum of 12 in (304.8 mm) straight pipe section to the closest bend. S Maintain at least 12 in. (304.8 mm) straight pipe length to the muffler shell inlet and from the outlet stubs. S To prevent rusting, provide sufficient clearance between the muffler and the ground surface. Also, position the muffler such that accidental abuse (such as by a weed trimmer, lawn mower etc.) of the painted surface is avoided. S Insulating the muffler with Armaflext tape is recommended. EXTERIOR WALL MUFFLER TO DWELLING VAPOR LINE A11543 Fig. 7 – Muffler Installation Table 1—MIN/MAX AIRFLOW The indoor airflow delivered by this system varies significantly the system will deliver full capacity at all outdoor temperatures. based on outdoor temperature, indoor unit combination, and Minimum and maximum air flows can be adjusted from these system demand. The air flows on these tables are for duct design numbers in the Infinity Control Heat Pump Setup screen. considerations. Duct systems capable of these ranges will ensure Cooling --- Comfort Mode Max Capacity Min Capacity Minimum Cooling (Dehum or Zoning) 24 726 651 398 36 1168 651 398 48 1394 1186 693 60 1650 1186 693 Size Cooling --- Efficiency Mode Size Max Capacity Min Capacity 24 949 830 36 1334 830 48 1593 1355 60 1885 1355 Heating --- Comfort Mode Size Max Capacity Min Capacity 24 698 440 36 1140 451 48 1354 751 60 1354 751 Heating --- Efficiency Mode Size Max Capacity Min Capacity 24 900 750 36 1350 518 48 1600 890 60 1750 901 9