Download Installation and Operating Instructions
Transcript
USonic™ US-XX Series 6.2 Transducer Specifications Sensor Material: CPVC Pressure: -10 to 50 psig 2" NPT / BSP Process Connection Operating Temperature: -40 to 158°F (-40°C to 70°C) Beam Angle: Conical, 10° typical, at the 3 db down point 6.3 Enclosure Specifications US - 1X PBT-RF (Valox 420 SEO UV Stabilized) to NEMA 4X (IP 66) 3/2" NPT / M20 Electrical / Conduit Entries US - 2XCast Aluminum Rated to NEMA 4X, IP 66, IP 68 (3m / 72h) 3/4" Electrical / Conduit Entries 6.4Approvals FM / FMc Model US-11, US-12 Intrinsically Safe for use in Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0, AEx / Ex ia, Group IIC in accordance with Entity requirements and Control Drawing 420-0004-289-CD; Nonincendive for use in Class I, Division 2, Groups A, B, C and D and Class I, Zone 2, Group IIC; Suitable for use in Class II and III, Division 2, Groups F and G; Dust-Ignitionproof for use in Class II and III, Division 1, Groups E, F and G Indoor and Outdoor, Type 4, 4X IP65 Hazardous (Classified) Locations. Model US-21, US-22 Intrinsically Safe for use in Class I, II and III, Division 1, Groups A, B, C, D, E, F and G and Class I, Zone 0, AEx / Ex ia, Group IIC in accordance with Entity requirements and Control Drawing 420-0004-272-CD: Nonincendive for use in Class I, Division 2, Groups A, B, C and D; Suitable for use in Class II and III, Division 2, Groups F and G; Dust-Ignitionproof for use in Class II and III, Division 1, Groups E, F and G; Explosionproof for use in Class I, Division 1, Groups A, B, C and D Indoor and Outdoor, Type 4, 4X, IP 66, IP 68 (3m / 72h) Hazardous (Classified) Locations. 52