6.4 Approvals (Continued)
IECEx
Ex ia IIC T5
FMG05.0001X
IEC – 60079 – 0 – General Requirements 2004-04
IEC – 60079 – 11 – Intrinsic Safety 1999-04
Install per 420-0004-312-CD
ATEX-NEMKO
II 1 G Ex ia IIC T5 US2X - IP66, IP68
NEMKO 05 ATEX 1271X
EN 60079-0:2006
EN 60079-11:2007
EN 60079-26:2004
The insulation between the intrinsically safe circuit and the frame of
the electrical apparatus or parts which may be earthed are capable of
withstanding 500 vac.