Download ASDA A2-E EtherCAT Interface Servo Drive User Manual

Transcript
Chapter 7 Alarm List
7.1 EtherCAT Communication Fault Messages
Emergency Object
Byte
Content
0
1
Emergency Error
Code
2
Error
register
3
4
5
Panel Alarm Code
6
7
N/A
Fault Messages
(If ALARM code is not showed here, please refer to the User Manual)
Display
AL185
Fault Name
Fault Description
Communication
disconnected
EtherCAT link is disconnected
Node guarding or
AL170 Heartbeat error
(Servo On)
Node guarding or
AL180 Heartbeat error
(Servo Off)
Clearing
Method
6040h fault reset
Error about node guarding or heartbeat
6040h fault reset
of CANopen protocol
Error about node guarding or heartbeat
6040h fault reset
of CANopen protocol
CANopen SDO
AL111 receives buffer
overflow
SDO Rx buffer overflow is detected
(receive two or more SDO packets in
1ms).
6040h fault reset
CANopen PDO
AL112 receives buffer
overflow
PDO Rx buffer overflow is detected
(receive two or more PDO (same
COBID) packets in 1ms).
6040h fault reset
Index error occurs
when accessing
The specified Index in the message
AL121
CANopen PDO
does not exist.
object.
6040h fault reset
Revision November 2013