Download USER MANUAL

Transcript
Chapter 8
DL-4 Commands
Message Id = 54
Field
Data
1
Header
2
Action, see Table 37
3
4
Bytes
Format
Units
Offset
-
-
0
4
Enum
none
H
GroupName1
12
Char[]
none
H+4
GroupName2
12
Char[]
none
H+16
Table 37: Action
Binary Value
ASCII Value
Description
0
ADD
Add a group
1
DEL
Delete a group
2
CLEAR
Erase all groups
3
COPY
Copy one group to another
Table 38: GROUP Default Configuration
Parameter
Group table
Power-On
no change
Freset
Only DEFAULT group, see Page 106
Stored in NVM
YES
8.15.1 Factory-Reset DEFAULT Group
The factory-reset DEFAULT group is defined as follows:
•
•
•
•
•
•
•
•
•
•
RANGECMPB ONTIME 10
ALMANACB ONCHANGED
RAWEPHEMB ONCHANGED
IONUTCB ONCHANGED
RTCAOBS ONTIME 1
RTCAREF ONTIME 10
RXSTATUSEVENTB ONNEW
HWLEVELSB ONTIME 60
POSAVE 0.01
INTERFACEMODE COM2 NONE RTCA OFF
You may edit or delete the factory-reset DEFAULT group.
106
DL-4 User Manual Rev 3