LOW LIMIT LOW LIMIT FAIL LOW LOW LIMIT PASS CALIBRATION RESISTANCE RESISTANCE RESISTANCE [1M - (1M x 10%)] [1M + (1M x 10%)] 1 Megohm 900Kilohms 1.1 Megohms HIGH LIMIT PASS HIGH LIMIT RESISTANCE CALIBRATION [15M? - (15Megohms RESISTANCE x 10%)] HIGH LIMIT FAIL HIGH RESISTANCE [15Megohms + (15M x 10%)] 15 Megohms 16.5 Megohms 13.5 Megohms C.) The table below specifies which numbered resistances on the circuit board correspond to the optional low limit and the optional high limit. Solder the appropriate resistors in these places. D.) Assemble the unit and mark the appropriate places on the label for the optional limits. E.) It is recommended to turn the rotary switch to the optional positions and measure the resistance from the tip to the body of the plug with an ohmmeter to verify the resistances. NOTE: Two (three for position 10) resistor locations are connected in series are provided in case resistors need to be added to achieve the desired total resistance. Solder a shorting wire across the resistor locations that are not used. MAINTENANCE Wipe the plug periodically with alcohol. Limited Warranty Vermason expressly warrants that for a period of one (1) year from the date of purchase, Vermason Limit Comparators will be free of defects in material (parts) and workmanship (labor). Within the warranty period, a credit for purchase of replacement Vermason products, or, at Vermason’s option, the product will be repaired or replaced free of charge. If product credit is issued, the amount will be calculated by multiplying the unused portion of the expected five year life times the original unit purchase price. Call our Customer Service Department at 0044 (0) 1462 672005 for a Return Material Authorization (RMA) and proper shipping instructions and address. Please include a copy of your original packing slip, invoice, or other proof of date of purchase. Any unit under warranty should be shipped prepaid to the Vermason factory. Warranty replacements will take approximately two weeks. If your unit is out of warranty, Vermason will quote repair charges necessary to bring your unit up to Vermason factory standards. Call Customer Service at 0044 (0) 1462 672005 for proper shipping instructions and address. Ship your unit freight prepaid. Figure 2. Optional low limit Designated resistors on circuit board Low limit fail low R1, R1A (*connected in series) Low limit pass R2, R2A (*connected in series) Optional high limit Designated resistors on circuit board High limit pass R9, R9A (*connected in series) High limit fail high R10, R10A, R10B (*connected in series) Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products. Limit of Liability In no event will Vermason or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. UNIT C, 4TH DIMENSION, FOURTH AVENUE, LETCHWORTH, HERTS, SG6 2TD UK Phone: 0044 (0) 1462 672005, • E-mail: [email protected], Internet: Vermason.co.uk TB-7564 Page 2 of 2 © 2014 Vermason