E37 “No heaters found; the Maintain temperature is too high.”
Suggested Action: Review the Maintain temperature field under the Basic tab.
Modify the value, if appropriate. Consider deselecting heater Manual Select under
the Heater Options tab – Heater Selection (if selected). Select Recalculation and
review results. Ensure you have chosen an appropriate Heater Technology (Series or
Parallel) under Heater Options tab.
E38 “No heaters found; the Operating temperature is too high.”
Suggested Action: Review the Operating temperature field under the Basic tab.
Modify the value, if appropriate. Consider deselecting heater Manual Select under
the Heater Options tab – Heater Selection (if selected). Select Recalculation and
review results. Ensure you have chosen an appropriate Heater Technology (Series or
Parallel) under Heater Options tab.
E39 “No heaters found; the Exposure Temperature is too high.”
Suggested Action: Review the Exposure Temperature field under the Basic tab.
Modify the value, if appropriate. Consider deselecting heater Manual Select under
the Heater Options tab – Heater Selection (if selected). Select Recalculation and
review results. Ensure you have chosen an appropriate Heater Technology (Series or
Parallel) under Heater Options tab.
E40 “No heaters found; the Startup temperature is too low.”
Suggested Action: Review the Startup temperature field under the Reference tab.
Modify the value, if appropriate. Consider deselecting heater Manual Select under
the Heater Options tab – Heater Selection (if selected). Select Recalculation and
review results.
E41 “No heaters found that are suitable for Pipe Heating.”
Suggested Action: Deselect heater Manual Select under the Heater Options tab –
Heater Selection (if selected). Review Maintain temperature and other
temperatures. Select Recalculation and review results.
E42 “No heaters found that are suitable for the Chemical
Exposure.”
Suggested Action: Review the Chemical Exposure field under the Reference tab.
Deselect heater Manual Select under the Heater Options tab – Heater Selection (if
selected). Select Recalculation and review results.
E43 “No heaters found that match the forced heater Construction
Options.”
Suggested Action: Review the selections made under Dielectric, Jacket Material
or Ground Path under the Heater Options tab – Heater Selection. Modify the
values, if appropriate. Also consider deselecting heater Manual Select under the
Heater Options tab – Heater Selection. Select Recalculation and review results.