Download TraceCalc Pro User Guide - Pentair Thermal Management
Transcript
To specify two layers of insulation, check the Two Layer Insulation System box. Once you are back on the Basic tab, you will see that the insulation properties are grayed out which indicates that a two-layer system is being used. Inner Layer Select the insulation type to be used in direct contact with the pipe from the list. In a two-layer system, the Inner Layer is often one that can withstand a high maximum pipe temperature, but may not have very good thermal properties (relatively high thermal conductivity). You can add, modify, or delete an insulation Type by clicking the insulation Type field. ellipsis by the Thickness Enter the inner layer Thickness. Enter a thickness sufficient to ensure that its outer surface temperature is below the temperature rating of the outer insulation. Outer Layer Select the insulation type to be used on top of the inner layer. In a two-layer system, the Outer Layer is often one that has very good thermal properties (relatively low thermal conductivity) but cannot withstand a high pipe temperature without a primary heat barrier. You can add, modify, or delete an insulation Type by clicking the insulation Type field. ellipsis by the Thickness Enter the Thickness of the outer layer. Be sure that the temperature gradient results in an acceptable temperature for the product’s rating at the interface. Over Size Insulation Over size insulation applies to when the thermal insulation inner diameter must be larger than the nominal outer diameter of a particular pipe in order to accommodate the heating cable. Over sizing is not necessary if the insulation is compressible, or if the pipe is large. Click the Use Over Size Insulation box if you wish to specify over sized insulation for your heat-tracing design. There is no need to enter a value in the Over Size Diameter box as the program will automatically pick the dimension specified in the Pipe Size Table, which will often be the next largest size insulation to fit your pipe diameter. To see the value that has been picked, close then reopen the Insulation Advanced Options dialog box. You can override this automatic selection by entering a value, which will only be used for this line. The program will base its calculations on this over sized insulation. Temperatures For a complete design and product selection of a heat-tracing system, TraceCalc Pro must have information about the following temperatures: Maintain The Maintain temperature is the desired temperature at which you want to maintain the pipe by the use of heat tracing. TraceCalc Pro User Guide H57159 (01/14) 5 Designing Your Project 43