Troubleshooting Page 143 of 187 Priority 1 Error Message A fatal IOException occurred when calling the specified remote server: %1. Possible Cause 1) Cannot have I/O communication with the remote server using HTTP. 2) Exceptions occurred when calling methods in the remote server, causing failure to return data. Solution 1) Check that the server is running and can be connected. 2) Check that Appeon Server residing in the server is started. 3) If both network and Appeon Server work correctly, send the log files on the local machine and the remote server to the Appeon technical support engineers. Error 11026 Priority 0 Error Message An unexpected exception occurred and caused the ClusterNotify thread to stop! Possible Cause An unknown error terminated the HTTP communication. Solution Send the Appeon Server log files to the Appeon technical support engineers. Error 11027 Priority 1 Error Message An unexpected exception occurred and resulted in failure to retrieve status of the server: %1. Possible Cause An unknown exception caused the failure to get the server status. Solution Please send Appeon Server log files to the Appeon technical support engineers for in-depth investigation. Error 11028 Priority 10 Error Message Application server connection error! Possible Cause The network is disconnected. Or the application server is shut down. Solution Check that the network can be connected, and application server can be accessed. Error 11029 Priority 10 file://C:\Documents and Settings\Administrator\Local Settings\Temp\1\~hh6081.htm 5/16/2013