HG-100K/LE/TH User’s Manual
Figure 41: Live View display options
9.2.6. Camera Orientation
The HG-100K/LE/TH cameras allow different mounting orientation options. MotionCentral
allows the orientation of the Live View or Playback to match the physical orientation of the
camera setup. This information is available in the border data.
1.
Select the System Tab from the Control Panel.
2.
Use the Camera Orientation drop-down list to select the orientation that matches the
physical setup.
9.2.7. Select Camera Orientation in Live View
1. Select the View tab below the Live View window.
2.
To use the same camera orientation as selected in the System Tab, check the Use Camera
Orientation box.
9.2.8. Control Light Source
1.
Select the Color tab below the Live View window.
2.
Use the Light Source drop-down list to select from the following Light Source options:
• Daylight
•
Tungsten
•
Metal Halide
•
User (default setting)
9.2.9. Correct White Balance
Redlake
1.
Select the Color tab below the Live View window.
2.
Set the Light Source drop-down list to User.
3.
Select a neutral-gray target object in the field of view illuminated by the same lighting
used during recording. A photographic gray card is ideal.
4.
Click on the White Balance reticle button and move the reticle so that the central box is
located completely within the target object.
5.
Observe the reticle pixel values and adjust the exposure setting or illumination of the
target object until none of the values is at or near saturation (255).
6.
Click the Apply button until all pixel values are within a few counts of each other and/or
the color of the scene displays true.
2/15/2005