Download Manual
Transcript
Technical data Sensor module Protection class housing version Measuring value recording interval Measuring range temperature sensors Accuray temperature measurement Accuracy analogue interfaces Temperature range operation logical (HIGH) logical (LOW) Battery Supply voltage (external at PCB version) Undervoltage alarm Weight without / with battery Dimensions L x W x H approx. IP 65 10 s – 1 year -40 °C ... +110 °C, resolution 0.1 °C, 1 channel typ. ±1.5 °C @ 20 °C, ± 2.5 °C in the whole temperature range typ. ±50 mV (0...10 V typ. ±100 mV) -25 °C ... +70 °C Vcc 0.3 V ... Vcc GND GND+0.5 V lithiumthionylchlorid, 3.6 V, size 2/3 A 7.0 - 30.0 V, 50 mA < 2.85 V approx. 170 / 190 g 82 x 80 x 57 mm Repeater module Protection class housing version Temperature range operation Power supply with power supply unit Supply voltage (external) Battery optional Weight Dimensions L x W x H approx. IP 65 -25 °C - +70 °C 2-pole connecting terminal 7 – 24 V , 50 mA lithiumthionylchloride, 3.6 V, size LR14 approx. 350 g 110 x 75 x 55 mm 69