Download Watson TSQ Module 1.0 User Guide Version A
Transcript
Glossary: N.D. (no data) Data is not in Watson. needle draw position offset The difference in the distance of the needle from the bottom of the vial from its default position. negative peak A peak characterized by signal levels that drop below the baseline level of the detector. neighboring amino acid The amino acids on either side of the cleaved amino acid. NL An abbreviated form of the words normalized level. This shortened form is used to save space in the header, for example, NL: 1.98e+003 (1.98 x 103). nominal sample time Protocol definition. The theoretical relative time a sample was taken from a subject after a treatment administration. non-serial subject (sparse sampling; composite profile) Protocol definition. A group of subjects that can be sampled only once or a limited number of times after treatment administration. It is not possible to study a subject's time vs. concentration profile. To create a time vs. concentration response profile for a treatment, a subject group dosed at the same time are divided into subsets of subjects that are sampled at different time points. Sample concentrations at the same time point are averaged together, and then the averages at the time increments are combined to form the time vs. concentration profile. no peak Not calculable. No data was returned from the instrument for the sample or the Watson application is unable to calculate a solution for the regression. Not Reportable: user definable string User assigned flag. no sites Amino acids in a sequence that follow an amino acid listed are not susceptible to digestion. For example, trypsin_k digests at Lysine (K), but if the K follows a Proline (P) in the sequence, it will not be digested. Thermo Scientific no waste injection A technique that injects the exact amount of sample requested. Of the three injection modes, the no waste injection mode uses the least amount of sample, but it is also the least precise. Use this injection mode to conserve sample. nominal molecular weight The calculated mass of a molecule based on the integer mass number of the most abundant isotope of each element, for example, C = 12, H = 1, and O = 16. normal scan types Scan types that are full and SIM. Normal scan types all have the same scan rate and provide unit resolution. normalization A data analysis procedure where all peaks are reported with heights relative to the highest peak height or area in the chromatogram, spectrum, or map. See also: fixed Y-axis normalization mode normalize Y-axis normalization mode normalize spectra The action of normalizing spectra to a common base peak intensity instead of using the raw intensities from the raw file before it generates correlation results. Normalizing the spectra corrects for intensity discrimination in the correlation results that can occur if spectra with significantly different absolute peak intensities are used. normalize Y-axis normalization mode A display mode, which is available for the Spectrum view, that sets the vertical scale equal to the height of the largest peak in a mass spectrum. In the normalize display mode, the software always displays the largest peak in the spectrum at full scale. See also: fixed Y-axis normalization mode nucleic acid Biologically occurring poly-nucleotides showing the nucleotide residues linked in a specific sequence by phosphodiester bonds, for example, DNA and RNA. Watson TSQ Module User Guide 133