10.1.2 Setpoint value
The (main) setpoint value is the setpoint value on which the control is based, when no standby
or boost function is activated.
Setpoint value
After activating the key, a
window is opened in which an
entry can be carried out as
described under Chapter 6.1.
Display per zone: Adjusted
setpoint value and actual value
10.1.3 Manual mode
A temperature control with temperature sensor, temperature controller and heating element is
possible only in case of closed control system. In case of failure of the temperature sensor
(open control system), it is not possible to control the process temperature. In case of older
tools without temperature sensors in the control system, the operation of the zone is possible
only in manual mode or in leading zone mode.
For this case TEMP-Soft offers two operating modes; manual mode or leading zone mode (see chapter
10.1.6).
With manual mode, the operator can adjust the required heating capacity in percent as a degree of
operation. In case of the degree of operation a value is involved between 0 and 100, which represents the
percentage content for the switched-on control outlet (0% = completely switched off; 100% = continuously
switched on).
If a sensor defect occurs during standard operating mode, then the temperature control notes the average
degree of operation at last output in the regulation. In case of selection of manual mode, the temperature
controller proposes this degree of operation in manual mode.