10.1.15 Heat ’n’ Dry
Heat ’n’ Dry is enabled for single zones.
The entry is to be carried out in the window, that is opened as described under chapter
6.1.2 and 6.1.3.
Function only available for series TEMP-Command and multi-channel controllers of type
flexotemp ® MCU/PCU from HEX file version 1309.
The key for the function call is only displayed in the operator interface, when all checks
(e.g. for HEX file version) were executed successfully by TEMP-Soft.
When molds are stored for a longer time, the insulating material for the electrical heating elements can draw
moisture. This moisture leads to leakage currents with connected protective conductors, that cause faultcurrent circuit breakers to disconnect and prevents the heating-up.
Heat ’n’ Dry executes a gentle heating-up with stepwise increasing of the power supply. The leakage current
is permanently checked. The moisture is completely dried by a setpoint value of 110°C.
The heating-up on the final setpoint value starts first, when it is assured, that
• the error current lies below a adjustable limit value
• in the heating elements is no longer moisture.
Set parameter for activation of
Heat ’n’ Dry for zones.
OFF = Function inactive
ON = Function active
The current adjusted value of the
parameter is displayed in the
zones.