Download Hunter Engineering RKHD Specification Sheet

Transcript
RKHD Heavy Duty Alignment Pit System
Pit Rack
LAY-OUT
Construct pit per referenced forms.
RECOMMENDED MINIMUM WIDTH
15 ft. (4572 mm)
EXAMPLE
SHOWN HAS A
TURNPLATE
SECTION WITH
TWO RUNWAY
SECTIONS
HANDRAIL AND
STEPS ARE
CONTRACTOR
SUPPLIED TO
LOCAL CODE
PIT DEPTH:
24 in. (610 mm)
OR
30 in. (762 mm)
PIT FLOOR SPECIFICATION:
4 in. THICK , 3000 PSI MINIMUM
FOR AN EXISTING FLOOR
(6 in. THICK , 3000 PSI
RECOMMENDED FOR
A NEW FLOOR)
RECOMMENDED
MINIMUM
72 in. (1829 mm)
64 in.
(1626 mm)
DRAIN
EDGING,
HANDRAIL AND
STEPS ARE
CONTRACTOR
SUPPLIED
PLUS 46 in.
(1168 mm)
FOR EACH
SET OF
RUNWAY
SECTIONS
33 in.
(838 mm)
REAR WALL
SPECIFICATION:
6 in. THICK,
3000 PSI MIN.
40 in.
(1016 mm)
OR TO
CUSTOMER
SPEC.*
Anchoring Details (inches)
The following items are to be supplied by the customer:
Concrete to construct pit / Concrete reinforcement / Electrical fixtures, wiring, and power (if necessary) / Piping /
Pit ventilation materials / Drainage materials / Edging / Railings / lifting equipment for installation.
Form 6947-T, 03-15b
Copyright © 2015, Hunter Engineering Company