Download Dell OpenManage Server Administrator Version 7.0 Command Line Interface Guide
Transcript
Type: omreport chassis fans index=0 -outa fans.txt or omreport mainsystem fans index=0 -outa fans.txt Fans.txt now reads as follows: Index : 0 Status : OK Probe Name : System Board Fan 1 RPM Reading : 2380RPM Minimum Warning Threshold : 600RPM Maximum Warning Threshold : 5700RPM Minimum Failure Threshold : 500RPM Maximum Failure Threshold : 6000RPM Index : 0 Status : OK Probe Name : System Board Fan 1 RPM Reading : 3001RPM Minimum Warning Threshold : 700RPM Maximum Warning Threshold : 5500RPM Minimum Failure Threshold : 500RPM Maximum Failure Threshold : 6000RPM You can use a text editor to insert the time that each block of data was captured. In comparing the two snapshots for fan probe 0, you can see that the second report shows several changes. The reading of fan RPM has increased by 621 RPM but is still within normal range. Someone has raised the minimum warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM. Selecting a Format for the CLI Command Output You can specify a format for the CLI command results. The format determines how the command output is displayed. If the command results are directed to a file, the format is captured by the file to which you write the command results. 284 Working With CLI Command Results